Free 2021 NS0-173 Dumps 100 Pass Guarantee With Latest Demo [Q32-Q54]

Share

Free 2021 NS0-173 Dumps 100 Pass Guarantee With Latest Demo

Prepare NS0-173 Question Answers Free Update With 100% Exam Passing Guarantee [2021]


Network Appliance NS0-173 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Compute Hardware components, Configuration, High availability, SAN Boot, UCS Manager
Topic 2
  • Virtualization Hypervisor Solutions, SAN Boot
Topic 3
  • Storage Hardware components, Configuration, High availability, SAN Boot
Topic 5
  • Networking Hardware components, Configuration, High availability, SAN Boot

 

NEW QUESTION 32
When FCoE is configured in a FlexPod environment, which step is required?

  • A. Create a VSAN to support FCoE for the FC uplink.
  • B. Assign a VSAN to the server uplink port on the Cisco Fabric Interconnects.
  • C. Assign a VLAN to the FC Uplink port on the Cisco Fabric Interconnects.
  • D. Create a VSAN within service profiles.

Answer: B

 

NEW QUESTION 33
A customer has installed FlexPod and verified that all wiring connections are correct. However, the customer cannot see any FC LUNs from the NetApp AFF systems.
In this scenario, which three configuration elements should the customer verify? (Choose three.)

  • A. MTU configuration
  • B. igroup configuration
  • C. FC portsets
  • D. FC zoning
  • E. ALUA settings

Answer: A,B,C

 

NEW QUESTION 34
A customer wants to extend a Layer 2 network over a Layer 3 Nexus 9000 infrastructure.
Which Layer 2 overlay scheme accomplishes this task?

  • A. STP
  • B. VXLAN
  • C. vPC
  • D. EIGRP

Answer: B

Explanation:
XLAN tunnels the Layer 2 network over the Layer.

 

NEW QUESTION 35
Your customer has a FlexPod implementation and wants to use life-cycle management to validate, monitor, and optimize the FlexPod infrastructure.
In this situation, which management tool should your customer use?

  • A. Cisco UCS Director
  • B. NetApp OnCommand Unified Manager
  • C. Cisco UCS Manager
  • D. NetApp Converged System Advisor

Answer: A

Explanation:
Cisco UCS Director can be an integral companion for FlexPod because it allows holistic management through centralized automation and orchestration from a single, unified view. When FlexPod and Cisco UCS Director are combined, IT can shift time and focus from managing infrastructure to delivering new service innovation. Used together, FlexPod and Cisco UCS Director deliver:

 

NEW QUESTION 36
A customer with a FlexPod Datacenter design that uses a 4-node FAS8200 for storage wants to add a new workload that requires high performance. The customer needs to nondisruptively move some workloads from the existing FAS system to the new storage.
Which storage system would satisfy the requirements?

  • A. E2700
  • B. FAS2700
  • C. AFF A300
  • D. EF570

Answer: D

 

NEW QUESTION 37
Your customer wants assurances that all aspects of FlexPod are highly available.
Which statement is correct in this scenario?

  • A. Cisco UCS Manager maintains a replica of configuration information.
  • B. Cisco UCS Manager automatically copies its configuration data to a remote data store.
  • C. Cisco UCS Manager contains multiple UCS domains.
  • D. Cisco UCS Manager uses active-active architecture.

Answer: A

Explanation:
The management and data plane of Cisco UCS is designed for high availability and redundant access layer fabric interconnects. In addition, Cisco UCS supports existing high availability and disaster recovery solutions for the data center, such as data replication and application-level clustering technologies.

 

NEW QUESTION 38
What are characteristics of the Cisco UCS 5108 blade chassis?

  • A. 4 RU, 8 half-width UCS B-series blades, 40 Gbps I/O bandwidth
  • B. 4 RU, 6 half-width UCS B-Series blades, 160 Gbps I/O bandwidth
  • C. 6 RU, 8 half-width UCS B-series blades, 160 Gbps I/O bandwidth
  • D. 6 RU, 6 half-width UCS B-series blades, 80 Gbps I/O bandwidth

Answer: C

 

NEW QUESTION 39
A customer is using a FlexPod implementation that has 10 Gbps uplinks from the B-Series chassis to the fabric interconnect. The customer wants to upgrade the links to 40 Gbps.
In this scenario, which model of Cisco UCS server IOM is required?

  • A. 0
  • B. 2204XP.
  • C. 1
  • D. 2208XP

Answer: B

Explanation:
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP+ ports that connect the blade chassis to the fabric interconnect.

 

NEW QUESTION 40
A customer with a FlexPod Express solution wants to enable remote access to the NetApp storage component.
In this scenario, which two access methods are recommended? (Choose two.)

  • A. SSH
  • B. SAML
  • C. RDP
  • D. Telnet

Answer: A,D

 

NEW QUESTION 41
Your customer has a FlexPod configuration with a 4-node NetApp AFF A300 storage cluster that uses only NSE drives.
Which two solutions allow the customer to expand the current storage system? (Choose two.)

  • A. a DS4246 with twenty-four 6 TB NL-SAS HDDs
  • B. a DS224C with twenty-four 3.8 TB SSDs
  • C. a two-node FAS8200 with a 4 TB NL-SAS HDD
  • D. a two-node AFF A200 with a 3.8 TB NSE SSD

Answer: B,C

 

NEW QUESTION 42
Two data centers are 75km apart. The customer wants to deploy a FlexPod solution in each data center to maintain high availability between the two sites with minimal possible data loss.
In this scenario, which technology would you use at the NetApp storage layer?

  • A. SnapVault
  • B. SnapMirror
  • C. FlexArray
  • D. MetroCluster

Answer: D

 

NEW QUESTION 43
Click the Exhibit button.

The total number of servers that a Cisco UCS Mini chassis supports is set to a maximum of how many hosts as shown in the exhibit?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 44
A customer is designing a FlexPod solution to use both NFS and iSCSI for connectivity, including traditional FC for legacy applications. The Cisco UCS Fabric Interconnects will be connected to both Nexus 9000 Series switches and FC switches.
Which UCS capability allows you to accomplish this task?

  • A. unified ports
  • B. FC uplink ports
  • C. VSANs
  • D. SAN pin groups

Answer: A

 

NEW QUESTION 45
A customer has deployed a FlexPod Datacenter with Red Hat Enterprise Linux OpenStack Platform. The Cinder storage volumes that are attached to the Nova instances are not available.
Based on the terms of the cooperative support model, which three companies would the customer use to open a support case? (Choose three.)

  • A. NetApp
  • B. VMware
  • C. Red Hat
  • D. Cisco
  • E. Microsoft

Answer: A,C,D

 

NEW QUESTION 46
A customer recently configured its Cisco UCS, and within the Chassis Discovery policy, they set the link group preference to Port Channel.
Which two benefits would they derive from this link group preference? (Choose two.)

  • A. All the links between the Cisco Fabric Interconnects and chassis IOM are pinned.
  • B. All the links between the Cisco Fabric Interconnects and chassis IOM are shared.
  • C. Traffic is load balanced across the links.
  • D. Each blade has an assigned Cisco Fabric Interconnects link.

Answer: B,C

 

NEW QUESTION 47
After you install a FlexPod infrastructure at a customer site, you need to migrate the existing Vmware virtual machines off the infrastructure that was used before FlexPod was installed.
Which VMware vSphere feature accomplishes this task?

  • A. vSphere DRS
  • B. VM Component Protection
  • C. vSphere HA
  • D. vMotion

Answer: D

 

NEW QUESTION 48
A customer wants to deploy a performance-sensitive workload while leveraging NetApp Snapshot technology and technologies such as NAS and SAN.
Which architecture satisfies these requirements?

  • A. NetApp SolidFire
  • B. NetApp AFF
  • C. NetApp StorageGRID
  • D. NetApp EF-Series

Answer: A

 

NEW QUESTION 49
A service provider is designing a FlexPod configuration to host multiple customers in a hybrid cloud environment, where IP address-range conflicts might arise on the shared storage.
Which NetApp feature should be enabled to prevent these conflicts?

  • A. SVMs
  • B. broadcast domains
  • C. failover groups
  • D. IPspaces

Answer: D

 

NEW QUESTION 50
A customer is planning to deploy a FlexPod solution for a large scale SAN requirement that uses the FC protocol. The customer plans to use Smart Zoning in the configurations to reduce the number of TCAM entries in the zoning process.
In this scenario, which design would enable the customer to use Smart Zoning?

  • A. storage connected to Cisco MDS switches
  • B. storage connected to Cisco Nexus 5000 Series switches
  • C. storage directly connected to Cisco UCS Fabric Interconnects
  • D. storage connected to Cisco Nexus 9000 Series switches

Answer: A

 

NEW QUESTION 51
You are designing a FlexPod solution that requires 32 ports running at 40 Gbps.
To satisfy this requirement, which Cisco Fabric Interconnect should you deploy?

  • A. 6296UP
  • B. 6332-16UP
  • C. 0
  • D. 6248UP

Answer: C

Explanation:
FI 6332 is a one-rack-unit (1RU) 40 Gigabit Ethernet, and FCoE switch offering up to 2.56 Tbps throughput and up to 32 ports. The switch has 32 40Gbps fixed Ethernet.

 

NEW QUESTION 52
An administrator decides to connect storage directly to UCS Fabric Interconnect to support FCoE within a FlexPod configuration.
In this scenario, which port type should be defined on the Fabric Interconnect ports that are connected to the storage controller?

  • A. server port
  • B. uplink port
  • C. appliance port
  • D. monitor port

Answer: B

 

NEW QUESTION 53
A FlexPod administrator is building a WWN pool for a server that has 33 ports.
In this scenario, what is the smallest size possible for the pool?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

 

NEW QUESTION 54
......

Dumps Real Network Appliance NS0-173 Exam Questions [Updated 2021]: https://www.passtorrent.com/NS0-173-latest-torrent.html